Sperm Concentration Count Test Kit

Sperm Concentration Count Test Kit

  • Format: Cassette
  • Specimen: human semen
  • Size: 3.0mm
  • Accuracy over 99%
  • Results read in 15 minutes
  • Methodology: Colloidal gold
  • Shelf time:2 years
  • Description
  • Instruction for Use
  • Ordering Information
  • Inquiry

Sperm Concentration Count Test Kit is an easy-to-use at home test for checking the concentration of sperm in semen, and conducting auxiliary clinical diagnosis of the infertility and self-evaluation male fertility of pre-pregnancy.

 

Features

  • Quick result read in 15 minutes
  • High accuracy over 99.6%
  • Relative sensitivity 97.5%
  • Relative specificity 98.3%

 

Package

Box of 2 kit, Ctn of 100 boxes

 

Each box contain:

  • Tow Pouches (each pouch contain: 1 cassette + 1 dropper + 1 desiccant)
  • Dropper x2
  • Collecting Cup x2
  • Staining Fluid x2
  • Washing Buffer x2
  • Insert x1

 

Fast diagnostic test for Sperm concentration (Colorimetric method) Operating Instructions

 

This product use the inert glass fiber membrane with high water absorption and the pore size of less than 0.5um to filter the semen, and sperm cells will be trapped on surface of the first layer of the membrane, and we use the staining fluid that can quickly dye sperm cells, the darker of the color, the more of sperm count on the filter membrane, and the count of sperm in the semen will be higher. Through comparing with the reference color (20million/ml specified by WHO) of well B on the test board, we know that if color of the test well A is lighter than color of the color card, the sperm count is positive, and if color of the test well A is darker than the color card, the sperm count is negative.

 

Intended UseFor qualitatively detecting sperm concentration of human semen in vitro, and conducting auxiliary clinical diagnosis of the infertility and self-evaluation male fertility of pre-pregnancy.

ModelCassette                User:for lay person

Contents

Each box contains four pouches(Two of the pouches respectively contains one test cassette, one desiccant and one dropper. The other two respectively contains one collecting cup, one desiccant.), two staining fluid , two Washing buffer and one operating instruction.

 

SPECIMEN COLLECTION

  1. Before testing, the subject shall mortify for 3-7 days, too short or too long abstinence time will affect the accuracy of diagnosis.
  2. Specimen collection of semen: Using masturbation to expel the semen directly into the sperm collecting cup.
  3. Liquefaction: To shake evenly the semen in the semen collecting cup, and standing it for 15 minutes, until the semen becomes fluid liquid.

 

TEST PROCEDURE

Before testing, we must read the instructions completely first

  1. Add the specimen: To take out an experimental board from a aluminum foil bag, and place it on the operation platform horizontally, using an accessory specimen-absorption pipe to absorb a tube of semen from the semen collecting cup, and dropping three drops of the semen into the white A hole, and then the semen saturates to surface of the membrane and dry.
  2. Add blue staining fluid: To add one drop of blue staining solution to test well A , and let it soak for 1-2 minutes.
  3. Add transparent washing buffer: Add two drops of transparent washing buffer to test well A, and let it soak for 1-2 minutes, and then read the results immediately.
  4. Read the results: Read the color of test well A , compare colors of test well A to reference Well B, the darker of the color, the more of sperm count, and report the results.

 

INTERPRETATION OF RESULTS

Results of naked eye observation: Compare colors of test well A to reference Well B.

Normal results: The color of test well A is darker than standard color of reference Well B, which shows that concentration of the sperm is normal.

Abnormal results: The color of test well A is lighter than standard color of reference Well B, such case belongs to oligospermatism; If well A is colorless, such case belongs to severe oligozoospermia or azoospermia.

 

Warnings & Precautions

For in vitro diagnostic use only

  1. This kit can only be used for diagnosis tests in vitro. To test human semen specimen and it does not apply to specimen of other body fluids.
  2. The kit shall be stored at room temperature, to avoid moisture. If the foil packaging is damaged, please not use.
  3. If the test card's package is opened, it shall be used as soon as possible, to avoid to be placed in the air for a long time, resulting in damp and failure.
  4. The kit is a kind of product used for primary test, any measured positive results shall be determined with other methods.
  5. When the tests are carried out for a large number of specimens, please make marks, to avoid confusion.
  6. Adding specimens and cleaning shall try to avoid bubbles, resulting effects to the test results.
  7. To observe the reaction results strictly according to time requirements of the instructions.
  8. This kit can only be used for one-time diagnosis in vitro, and the semen taken from different subjects or from the same subject at different times can not be used repeatedly.
  9. The kit must not be frozen or used after the expiry.
REF.DescriptionCBM/ctnKGS/ctn
L110401Sperm Concentration Test Kit.           Each box contain:                                         • Tow Pouches (each pouch contain: 1 cassette + 1 dropper + 1 desiccant)
• Dropper x2
• Collecting Cup x2
• Staining Fluid x2
• Washing Buffer x2
• Insert x1
0.0678

Contact Us